| Rearch on Carbonate Scaling in Reverse Osmosis Concentrated Water and Circulating Water Systems |
| Authors: ZHANG Xiao Ni,WU Wen Long,WANG Xu Wen |
| Units: 1.Henan Electric Power Research Institute, Henan Zhengzhou 450052,China |
| KeyWords: reverse osmosis concentrated water; circulating water system; carbonate scale; anti-scalants |
| ClassificationCode:TQ 085.4 |
| year,volume(issue):pagination: 2011, 31(5):84-88 |
|
Abstract: |
|
Scale is one of usual problems in reverse osmosis and circulating water systems. By comparing components of scales on reverse osmosis and in conderser tube, the change of pH, CO2 and carbonate ions, carbohydrate equilibrium have been compared and analyzed in reverse osmosis and circulating water systems.In the end, the selection of anti-scalants been suggested based on scaling characteristics. |
|
Funds: |
|
AuthorIntro: |
|
Reference: |
|
[1] 中华人民共和国水利电力部.火电厂垢和腐蚀产物分析方法[S].水利电力出版社,1986 |
|