| Study on the dehumidification of low pressure and high humidity air by different structure hollow fiber membranes |
| Authors: TANG Wei-hua, ZHANG Qi, ZHANG Long-long, LIN Bi-liang, LI Jun, WU Wen-hong |
| Units: The 718th Research Institute of CSIC |
| KeyWords: hollow fiber membrane;low pressure;air;dehumidification;structure |
| ClassificationCode:TQ028.8 |
| year,volume(issue):pagination: 2013, 33(6):78-82 |
|
Abstract: |
|
Three different structure fiber membrane components were used for low pressure and high humidity air dehumidification, and the influencing factors (inlet pressure, inlet flow rate, scavenging flow rate) on dehumidification performance were also studied. The results show that the membrane component with scavenging gas distributor has better dehumidification performance. Elevating inlet pressure and scavenging flow rate, decreasing inlet flow rate can also enhance the dehumidification performance. Under the operation pressure of 0.03MPa、inlet flow rate of 5 m3•h-1 and 30% scavenging flow rate, the membrane component with scavenging gas distributor can dehumidify the air from 95%RH to 43.5%RH. |
|
Funds: |
|
AuthorIntro: |
| 汤卫华(1980-),男,湖北襄阳,硕士,工程师。现主要从事膜分离技术研究。E-mail: perictwh@126.com |
|
Reference: |
|
[1] 李鑫, 李忠, 韦利飞, 等. 除湿材料研究进展[J]. 化工进展, 2004, 23(8): 811~815. |
|