| Study of membrane degassing technology for HCl removal |
| Authors: Wenjia Zhou1, Yue Jia*, Xiaolong Lu*,Chunrui Wu, Xuan Wang, Huayan Chen, Qijun Gao |
| Units: State key Laboratory of Hollow Fiber Membrane Materials and Processes, Tianjin Polytechnic University, Institution of Biological and Chemical Engineering, Tianjin 300387, China |
| KeyWords: Membrane degassing technology; hydrochloric acid; separation efficiency |
| ClassificationCode:TQ028.8 |
| year,volume(issue):pagination: 2014, 34(6):72-76 |
|
Abstract: |
|
Experiments study was carried out using the membrane degassing technology for HCl separation from hydrochloric acid solution. The effects of membrane area, the velocity of feed flow through the fiber lumen, and hydrochloric acid concentration on HCl removal efficiency were investigated, respectively. The results showed that HCl separation efficiency can be enhanced by increasing the membrane area and the feed velocity. Furthermore, lower hydrochloric acid concentration led to declined separation efficiency. Using the module with membrane area of ??1.0m2, the separation efficiency of HCl from 6mol/L hydrochloric acid solution achieved 85%, at a feed velocity of 0.12m/min and a vacuum pressure of 0.090MPa. |
|
Funds: |
| 国家自然科学基金青年科学基金项目(21306135),天津市自然科学基金青年项目(13JCQNJCOS800) |
|
AuthorIntro: |
| 吕晓龙(教授) ; 贾悦(副研究员) |
|
Reference: |
|
[1] 刘纪成, 杨晓进, 海热提等. 热耦合渗透蒸馏分离酸洗废水HCl的传质研究[J]. 环境科学与技术, 2012, 359 (2): 143-147. |
|
Service: |
| 【Download】【Collect】 |
《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com