| Study on boron rejection performance of SWRO membrane |
| Authors: FAN Wen-Wen,ZHANG Zhi-Yin,YE Xin-Nan |
| Units: China Nuclear Power Engineering Co. Ltd, Beijing 100840, China |
| KeyWords: boron;SWRO;boron rejection |
| ClassificationCode:TQ028.8 |
| year,volume(issue):pagination: 2015, 35(3):81-84 |
|
Abstract: |
|
Experiments of removing boron using SWRO membrane were carried out on a pilot equipment. Results show that boron rejection performance of test SWRO surpass BWRO & FILMTEC SWRO. Boron rejection at natural pH is 60%~80% and can reach above 98% by adjusting pH. When feed water pH≤8.0 boron rejection evidently raises following pressure increasing and the influence diminishes at pH≥9.5. In addition, boron rejection of SWRO is independent on recovery ratio and feed boron concentration. So improving feed water pressure and pH can effectively promote the boron removing performance of RO membrane. |
|
Funds: |
|
AuthorIntro: |
| 范雯雯(1983-),女,山东,硕士研究生,工程师,现主要从事核电厂放射性废物管理工作。E-mail:Lyla4065@163.com |
|
Reference: |
|
[1]M. Rodriguez Paastor, A. Ferrandiz Ruiz, ect. Influence of pH in the elimination of boron by means of reverse osmosis.[J]. Desalination, 2001, 140:145-152. |
|