| 饮用水超滤膜处理中试中的膜污染控制 |
| 作者: 1.天津大学 环境科学与工程学院,天津 300072;2.天津泰达自来水公司,天津 300457 |
| 单位: 1.天津大学 环境科学与工程学院,天津 300072;2.天津泰达自来水公司,天津 300457 |
| 关键词: 饮用水;膜污染;反洗;化学强化反洗(CEB);化学清洗;预氯化 |
| DOI号: |
| 分类号: TU 991.2 |
| 出版年,卷(期):页码: 2012, 32(4):81-86 |
|
摘要: |
|
采用中试规模的压力式超滤膜系统处理水厂的沉淀池出水,对试验期间的膜污染控制技术进行了研究。试验中采用了物理反洗,化学强化反洗(CEB),化学清洗和预氯化对膜污染进行控制。结果表明:物理反洗工艺对于膜污染的去除效果不明显;CEB是一种物理和化学方法相结合的在线清洗方法,能够有效地恢复膜比通量,平均恢复率达85 %;采用草酸进行化学清洗效果较好,4次清洗膜比通量平均提高了265 L/(h•m2•bar)。对膜反洗水的成分分析表明:铁和溶解性有机物是导致中试系统膜污染的主要因素。预氯化可以有效地减缓膜污染速率。 |
|
A pilot-scale low pressure ultrafiltration membrane system was used to treat the finished water from a sedimention tank in the waterworks, and membrane fouling control was investigated. Physical backwashing, chemical enhanced backwash (CEB), chemical cleaning and pre-chlorination were studied for membrane fouling control. Results showed that physical backwashing have a little effect on fouling control, however, CEB, an online cleaning mode could have a great effect on fouling control, and the average recovery rate of specific flux was 85%. The effect of chemical cleaning with oxalic acid was better, after cleaning, the average SF value was increased to 265 L/(h•m2•bar). Pre-chlorination could slow down the fouling rate. In addition, the composition of the eluent was analysed. The results revealed that iron and dissolved organic matter were the major factors for fouling. |
|
基金项目: |
|
作者简介: |
|
A pilot-scale low pressure ultrafiltration membrane system was used to treat the finished water from a sedimention tank in the waterworks, and membrane fouling control was investigated. Physical backwashing, chemical enhanced backwash (CEB), chemical cleaning and pre-chlorination were studied for membrane fouling control. Results showed that physical backwashing have a little effect on fouling control, however, CEB, an online cleaning mode could have a great effect on fouling control, and the average recovery rate of specific flux was 85%. The effect of chemical cleaning with oxalic acid was better, after cleaning, the average SF value was increased to 265 L/(h•m2•bar). Pre-chlorination could slow down the fouling rate. In addition, the composition of the eluent was analysed. The results revealed that iron and dissolved organic matter were the major factors for fouling. |
|
参考文献: |
|
[1] 刑卫红, 童金忠, 王焕章, 等. 微滤和超滤过程中浓差极化和膜污染控制方法研究[J]. 化工进展, 2000(1): 44-48.
|
|
服务与反馈: |
| 【Download】【加入收藏】 |
《膜科学与技术》编辑部 地址:北京市朝阳区北三环东路19号蓝星大厦 邮政编码:100029 电话:010-80492417/010-80485372 传真:010-80485372邮箱:mkxyjs@163.com
京公网安备11011302000819号