| 国产纳滤膜淡化高氟苦咸水基础研究 |
| 作者: 1.中国海洋大学海洋化学理论与工程技术教育部重点实验室,山东 青岛 266100; |
| 单位: 1.中国海洋大学海洋化学理论与工程技术教育部重点实验室,山东 青岛 266100; |
| 关键词: 国产纳滤膜;脱氟;苦咸水淡化 |
| DOI号: |
| 分类号: TQ028.8 |
| 出版年,卷(期):页码: 2015, 35(1):108-114 |
|
摘要: |
|
实验选取两种国产纳滤膜NF2A和NF3A进行纳滤膜淡化高氟苦咸水的基础研究,考察操作压力、温度、进水pH、进水氟浓度、总含盐量及运行时间对纳滤膜分离性能的影响,并测定膜的Zeta电位,同时简单比较两种膜。研究结果表明,两种纳滤膜处理高氟苦咸水的理想操作条件为:压力1.0~1.5MPa,温度20℃,进水pH=6.5左右,在此条件下NF3A纳滤膜的脱盐率为79%,脱氟率为90%,产水通量为53 L·m-2·h-1,NF2A纳滤膜分别为73%,73%和71 L·m-2·h-1,此外随进水氟浓度和总含盐量的增大,纳滤膜的脱氟和脱盐率降低,同时得出两种膜在长期运行72 h内膜性能基本保持稳定,最后测得NF3A和NF2A的Zeta电位分别为-22和-18 mV。这项研究为国产纳滤膜处理高氟苦咸水的实际应用提供了技术数据,有利于国产纳滤膜的发展和完善。 |
|
In this study,the performances of two domestic NF membranes (NF2A and NF3A) for defluorinating brackish water with high fluoride were studiedand compared.And the influences of pressure, temperature, pH,fluoride concentration, total dissolved solids and running time were studied by a pilot unit test.And the Zeta potential of the two NF membranes was detected.Then the optimum condition was identified as followings: Pressure 1.0-1.5MPa, Temperature 20℃, pH=6.5.Under this condition,the desalination rate, the defluorination rate and the water flux of NF3A membrane was 79%, 90% and 53 L·m-2·h-1, while that of the NF2A membrane was 73%,73% and 71L·m-2·h-1, respectively.And as a result of the increasing of fluoride concentration and TDS, the defluorination ratedecreased. Meanwhile,the results of long-term operation (72h) showed that the permeability of the membrane remained stable. Finally, the Zeta potential of NF3A and NF2A was -22 and -18 mV. This research will provide technical references to the practical application of domestic NF membranes in the treatment of brackish water, and promote and improve the development of domestic NF membranes. |
|
基金项目: |
| 高通量纳滤膜材料的规模化制备技术(2012AA03A602);MBR-NF处理世园会园区污水回用技术(12-1-3-56-nsh) |
|
作者简介: |
|
In this study,the performances of two domestic NF membranes (NF2A and NF3A) for defluorinating brackish water with high fluoride were studiedand compared.And the influences of pressure, temperature, pH,fluoride concentration, total dissolved solids and running time were studied by a pilot unit test.And the Zeta potential of the two NF membranes was detected.Then the optimum condition was identified as followings: Pressure 1.0-1.5MPa, Temperature 20℃, pH=6.5.Under this condition,the desalination rate, the defluorination rate and the water flux of NF3A membrane was 79%, 90% and 53 L·m-2·h-1, while that of the NF2A membrane was 73%,73% and 71L·m-2·h-1, respectively.And as a result of the increasing of fluoride concentration and TDS, the defluorination ratedecreased. Meanwhile,the results of long-term operation (72h) showed that the permeability of the membrane remained stable. Finally, the Zeta potential of NF3A and NF2A was -22 and -18 mV. This research will provide technical references to the practical application of domestic NF membranes in the treatment of brackish water, and promote and improve the development of domestic NF membranes. |
|
参考文献: |
|
[1]戴向前, 刘昌明, 李丽娟.我国农村饮水安全问题探讨与对策 [J].地理学报, 2007, 62(9):907-916. |
|
服务与反馈: |
| 【Download】【加入收藏】 |
《膜科学与技术》编辑部 地址:北京市朝阳区北三环东路19号蓝星大厦 邮政编码:100029 电话:010-80492417/010-80485372 传真:010-80485372邮箱:mkxyjs@163.com